Message: Re: Untitled Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

More Re: Untitled 

Forum: Geometry
Re: None Untitled (Victor)
Re: Feedback Re: Untitled (Gabriele Cosmo)
Re: None Re: Untitled (Victor)
Date: 10 Aug, 2011
From: Gabriele Cosmo <Gabriele Cosmo>

> When I create it and set sensitive detectors to the absorber and all of
> its daughters, I can't track any of the particles inside the sd.
> This happens when I use sizes which are mentioned above.
> 
> When I use the same construction, but I increase the size of absorber :
> length and width, but thickness is the same, I manage to track
> particles.

I don't see a reason why that should happen, unless there're
overlaps or your sensitive detector setup is not correct...
Note that if you're nesting parameterised volumes, you should use
the "nested parameterisation" feature!

Cheers, Gabriele