Message: Re: Change in the energy deposition/dose between G4.9.3.p02 and G4.9.4.p01 using a voxel phantom Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Idea Re: Change in the energy deposition/dose between G4.9.3.p02 and G4.9.4.p01 using a voxel phantom 

Forum: Geometry
Re: Question Change in the energy deposition/dose between G4.9.3.p02 and G4.9.4.p01 using a voxel phantom (Daniel Matthiń)
Date: 23 Mar, 2011
From: Vladimir Ivanchenko <Vladimir Ivanchenko>

Hello,

There is a result of simple test for C12 beam where water volume is sliced 1D:

http://vnivanch.web.cern.ch/vnivanch/verification/verification/electromagnetic/test44/geant4-09-04-patch-01/A_c12_water.gif

This result confirms that there is no visible deviation in physics when such geometry is used.

Likely you need to try to check how scoring in your voxels is done. geometry itself should not be an issue.

VI