Message: Change in the energy deposition/dose between G4.9.3.p02 and G4.9.4.p01 using a voxel phantom Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question Change in the energy deposition/dose between G4.9.3.p02 and G4.9.4.p01 using a voxel phantom 

Forum: Geometry
Date: 23 Mar, 2011
From: Daniel Matthiń <Daniel Matthiń>

Dear all,
I am using a voxel phantom with voxel sizes of 1x1x2.5 mm to simulate a radiation treatment. I observed that the dose in the designated tumor region increases by about 30% if I change from G4.9.3.p02 to G4.9.4.p01 without changing anything in the geometry or physics list. I also found that no differences occur if I use a single water box instead of the voxel phantom. I am using a gps multisource for the irradiation with C12 with energies between 170MeV/n and 270MeV/n.
Any help or advice is appreciated.
Daniel Matthiae

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: Change in the energy deposition/dose between G4.9.3.p02 and G4.9.4.p01 using a voxel phantom   (Vladimir Ivanchenko - 23 Mar, 2011)
2 Idea: Re: Change in the energy deposition/dose between G4.9.3.p02 and G4.9.4.p01 using a voxel phantom   (Pedro Arce - 28 Mar, 2011)