Message: low-energy tracks incorrectly stopped Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question low-energy tracks incorrectly stopped 

Forum: Fast Simulation, Transportation & Others
Date: 28 Nov, 2015
From: Tom Roberts <Tom Roberts>

If I shoot mu+ with momentum 0.01 MeV/c, they are stopped at the end of the first step and decay there. e+ with momentum 0.001 MeV/c are stopped at the end of the first step and annihilate there (in Vacuum!). Higher-energy particles do not do this.

I need to track such low-energy particles. How can I change this?

This is geant4-10-01-patch-01. I'm pretty sure this did not happen in 9.6 or earlier.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: low-energy tracks incorrectly stopped   (Artem Zontikov - 28 Nov, 2015)
1 None: Re: low-energy tracks incorrectly stopped   (Tom Roberts - 28 Nov, 2015)
(_ None: Re: low-energy tracks incorrectly stopped   (Artem Zontikov - 29 Nov, 2015)
2 None: Re: low-energy tracks incorrectly stopped   (Tom Roberts - 30 Nov, 2015)
1 Idea: Re: low-energy tracks incorrectly stopped   (Vladimir Ivanchenko - 04 Jan, 2016)
 Add Message Add Message