Message: Re: How to input energy spectrum data with more than 512 bins? Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: How to input energy spectrum data with more than 512 bins? 

Forum: Event and Track Management
Re: Question How to input energy spectrum data with more than 512 bins? (MaTao)
Date: 04 May, 2010
From: Quentin Cherel <Quentin Cherel>

Hi MaTao

I had the same thing, and I found the answer in the PrimaryGenerator.cc of the radioprotection example. It reads a .txt with energy and probability, the method here required the energy to be written with integer ( a simple conversion).

Quentin

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Question: Re: How to input energy spectrum data with more than 512 bins?   (MaTao - 06 May, 2010)
(_ None: Re: How to input energy spectrum data with more than 512 bins?   (michel maire - 07 May, 2010)