> What would be the strategy?

You can define a 'test volume' (thin box, for example) perpendicular to the z-axis large enough to capture all the beam at the position of interest.

No need to define it as a sensitive detector for your purposes. Simply add code in your UserSteppingAction (see link below):

> Are any examples where something like this is achieved?

/examples/extended/field/field04/src/F04SteppingAction.cc

http://www-geant4.kek.jp/lxr/source/examples/extended/field/field04/src/F04SteppingAction.cc#L65

(look for "TestPlane")