Message: Re: Tracking help !! Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Tracking help !! 

Keywords: TestEm4,energy deposition
Forum: Event and Track Management
Re: None Tracking help !! (vivek)
Date: 27 Jun, 2007
From: michel maire <michel maire>

User vivek wrote:

>> hi,
>> i am fairly new to geant and am trying to build a very simple example. 
>> In my simulation i have 4 segements of tin surrounded by copper and 
>> stainless steel shielding. I have only modified the geometry of TestEm4 to 
>> get my geometry. However its showing me the total energy deposited in all
>> the logical volumes whereas i require the cumulative energy deposition in 4 Tin segments only.
>> I tried to make my Tin segments sensitive but compiled with lot of errors.
>> Is there a way in which i can get around this problem without declaring sensitive
>> detectors? 
>> 

   in SteppingAction, you must check the volume in which you want collect
 energy deposition.

   See examples/novice/N03/SteppingAction.cc

  See also the geant4 FAQ
  