Message: Re: Different cuts for different materials / logical volumes Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Different cuts for different materials / logical volumes 

Keywords: step size
Forum: Event and Track Management
Re: Question Different cuts for different materials / logical volumes (I Cornelius)
Date: 16 Dec, 2002
From: michel maire <michel maire>

User Iwan Cornelius wrote:

>> And is there a way to assign a maximum step size for a
>> particular particle in a particular volume?

The simplest is to create it as a process. See examples/extended/electromagnetic/TestEm5 : The process Em5StepCut.hh is instancied in Em5PhysicsList::ConstructGeneral()

(see also Em5PhysicsListMessenger.cc)

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Question: Re: Different cuts for different materials / logical volumes   (Iwan Cornelius - 27 Jan, 2003)
(_ None: Re: Different cuts for different materials / logical volumes   (Makoto Asai - 27 Jan, 2003)
 Add Message Add Message
to: "Re: Different cuts for different materials / logical volumes"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews