Message: Re: Setting tracking cuts for logical volume Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

More Re: Setting tracking cuts for logical volume 

Keywords: Tracking cuts
Forum: Event and Track Management
Re: Question Setting tracking cuts for logical volume (Hugh Lippincott)
Re: Warning Re: Setting tracking cuts for logical volume (Gumplinger Peter)
Re: Question Re: Setting tracking cuts for logical volume (Hugh Lippincott)
Date: 16 Jan, 2007
From: Gumplinger Peter <Gumplinger Peter>

Hi Hugh,

I found your problem looking at the code G4UserSpecialCuts::PostStepGetPhysicalInteractionLength. This is likely not documented but it says there:

// min kinetic energy (only for charged particle)

at:

http://geant4www.triumf.ca/lxr/source/processes/transportation/src/G4UserSpecialCuts.cc#120

My guess is the user is expected to implement a production range cut for neutral secondaries if he/she doesn't want them to be tracked at all. This ekin special cut applies only to charged particles because only they can drop below a min. kinetic energy during tracking.

Peter

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: Setting tracking cuts for logical volume   (Vladimir IVANTCHENKO - 17 Jan, 2007)
2 More: Re: Setting tracking cuts for logical volume   (Peter Gumplinger - 17 Jan, 2007)
 Add Message Add Message