Message: Re: step lenght = 0 Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: step lenght = 0 

Keywords: step lenght = 0
Forum: Event and Track Management
Re: Question step lenght = 0 (gia)
Date: 03 Apr, 2005
From: Makoto Asai <Makoto Asai>

Occationally it happens. Typically, a (physics) process limits a step
at a point which is within the tolerance (10^-9 m) of a surface of a 
volume. In this case, the next step should have zero length, but the
point after this zero-length step belongs to the next volume.