Message: Re: Accessing Step Information Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

More Re: Accessing Step Information 

Keywords: Time Dependent Magnetic Field
Forum: Event and Track Management
Re: Question Accessing Step Information (Zach Hartwig)
Re: None Re: Accessing Step Information (Makoto Asai)
Re: Agree Re: Accessing Step Information (Zach Hartwig)
Date: 16 Mar, 2005
From: Gumplinger Peter <Gumplinger Peter>

Yes, I agree this is a great trick getting a handle to the G4RunManagerKernel. Only I did a quick search with Geant4-LXR source code browser and found not a single example (novice, extended, or advanced) that uses this (for me new) trick, nor can it be found at:

http://geant4.slac.stanford.edu/Tips/

or

http://wwwasd.web.cern.ch/wwwasd/geant4/support/faq.html

It really does allow access to all sorts of goodies and should be advertised more.