Dear Geant Users,

  I need help ..

Suppose I have a sample material, say Silicon.I irradiate it with photons of a particular energy. The photons interact with the material and produce secondaries, electrons and photons. I am interested in the secondary electrons. If I place a sensitive detector below the material, it registers a hit only if a primary particle, the photon impinges on the sensitive detector. What I want is for the sensitive detector to register a hit when the secondary electron impinges on it, because I want to accumulate the electrons and plot a spectrum. Right now, I'm using a counter in the mySteppingVerbose.cc to filter out the necessary particles and count them as they pass into the counter.

My questions are :

1 ) Is it possible to select the particle of our choice to be registered as a hit in the sensitive detector ? 2 ) Is it possible to have many sensitive detectors that are "sensitive" to different particles ?

  Thanks.

Manju Sudhakar.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: can sensitive detectors be used to filter out secondary particles .. ?   (michel maire - 24 Nov, 2004)
(_ Feedback: Re: can sensitive detectors be used to filter out secondary particles .. ?   (Manju Sudhakar - 21 Dec, 2004)
 Add Message Add Message
to: "can sensitive detectors be used to filter out secondary particles .. ?"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]