Message: Re: Secondary below production cut Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Secondary below production cut 

Forum: Event and Track Management
Re: Question Secondary below production cut (Alain Ferragut)
Date: 30 Aug, 2004
From: Vladimir IVANTCHENKO <vnivanch@mail.cern.ch>

On Mon, 30 Aug 2004, Alain Ferragut wrote:

> *** Discussion title: Event and Track Management
> Email replies to PublicHyperNews@slac.stanford.edu must include:
>   In-Reply-To: <"/eventtrackmanage/201"@geant4-hn.slac.stanford.edu>
>   Subject: ...change this to be about your reply.
> 
> Hi, When a secondary particle has a range below cut, is the user
> informed about the existence of this secondary, or is the particle just
> discarded without notice. My point is the following: I want to count how
> many secondary electrons are produced within a step, but I do not want
> to track them. Thanks,
> 

Hello Alain,

To remove secondaries below cut one can use a command

/run/particle/ApplyCuts

To control secondaries one have to use stepping or tracking actions. See 
examples. A good example is example/extended/electromagnetic/MuonProcesses 
in which secondaries are not tracked at all.

VI 

Inline Depth: