Message: Re: Stepsize limitation Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Stepsize limitation 

Forum: Event and Track Management
Re: Question Stepsize limitation (I Cornelius)
Date: 23 Mar, 2004
From: michel maire <michel maire>

 Apart from multiple scattering, one may have good reasons to limit the
 step size 'by hand'.
 In TestEm7 we plot the profile of the energy deposited by 160 MeV
 protons absorbed in 20 cm of water (Bragg peak). We limit the step size (say
 1 mm) in order to compute and plot the energy deposited in that step.