Message: Re: set low energy threshold for different regions Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Idea Re: set low energy threshold for different regions 

Forum: Event and Track Management
Re: Question set low energy threshold for different regions (Balder)
Date: 21 Feb, 2016
From: Vladimir Ivanchenko <Vladimir Ivanchenko>

Hello,

sorry for the late reply. This is a question to EM physics, in the appropriate forum a reply may come faster.

In Geant4 there is no possibility to set low limit for production threshold per region. This low limit is common. Cuts can be set per region. However, this is not a serious limitation from my point of view/ In particular in micro-dosimetry cuts should be indeed low.

VI

 Add Message Add Message
to: "Re: set low energy threshold for different regions"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]