Message: set low energy threshold for different regions Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question set low energy threshold for different regions 

Forum: Event and Track Management
Date: 02 Feb, 2016
From: Balder <Balder>

Dear geant4 experts, I'm using microdosimetry example in which there is two Regions (Target and World) and two physics lists are active (DNA and Standard) in the same run but the low energy edge is the same for both physics list (990 eV). I know I can change this by typing:

/cuts/setLowEdge 250 eV
or alternatively directly in the user physics list, in the optional SetCuts() method, using:
  G4ProductionCutsTable::GetProductionCutsTable()->SetEnergyRange(250*eV, 1*GeV);

the problem is that those commands set the low energy edge in both regions and I'm wondering if there is a way to set a different low energy limit for each region like: /cuts/setLowEdge 10 eV for Target region and /cuts/setLowEdge 250 eV for the World region.

Many thanks,

Balder.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: set low energy threshold for different regions   (Vladimir Ivanchenko - 21 Feb, 2016)
 Add Message Add Message
to: "set low energy threshold for different regions"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews