Hello,

When ionisation limits the step it is to produce a delta-ray, ie, an 
electron that is above the production threshold, and that will be 
tracked. All other electrons, below threshold, are indeed accounted for 
a continuous loss.

Marc

On 06/24/2013 03:09 PM, Kendall wrote:
> *** Discussion title: Event and Track Management
>
> Hi Michael,
>
> Yes your response was very clear and very helpful so thank you!
>
> It makes sense now that multiple scattering wouldn't limit the step
> since it is a continuous process. But the limiting process that gets
> listed is ionization...and that is continuous, is it not?
>
> Do you have any insight on this?
>
> Thank you in advance and I really appreciate all the help I've been
> given so far!
>
> -------------------------------------------------------------
> Visit this GEANT4 at hypernews.slac.stanford.edu message (to reply or unsubscribe) at:
> http://hypernews.slac.stanford.edu/HyperNews/geant4/get/eventtrackmanage/1121/1/1/1/1.html

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: MuMultipleScattering not listed   (Vladimir Ivanchenko - 24 Jun, 2013)
(_ None: Re: MuMultipleScattering not listed   (michel maire - 24 Jun, 2013)
 Add Message Add Message
to: "Re: MuMultipleScattering not listed"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]