Re: Question NaI detector energy acquisition (Sean Turnbull)
Re: None Re: NaI detector energy acquisition (michel maire)
Re: None Re: NaI detector energy acquisition (Sean Turnbull)
Date: 04 Sep, 2003
From: Vladimir Ivanchenko <Vladimir Ivanchenko>

On Thu, 4 Sep 2003, Sean Turnbull wrote:

> *** Discussion title: Event and Track Management
> Email replies to PublicHyperNews@slac.stanford.edu must include:
>   In-Reply-To: <"/eventtrackmanage/103/1/1"@geant4-hn.slac.stanford.edu>
>   Subject: ...change this to be about your reply.
> 
> If I use two materials, Air and a NaI detector joined together in a long
> cylinder, I would have to use a SD to distinguish energy added to the
> NaI detector and not added to the Air? Thanks for your help...
> 

If in the geometry description NaI is mixed  with air, then the only way 
is to distvinguish in SD. If NaI and Air are in differentvolumes - they 
are natiarally distiguished.

VI


Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Question: Re: NaI detector energy acquisition   (Sean Turnbull - 11 Sep, 2003)
1 None: Re: NaI detector energy acquisition   (Vladimir IVANTCHENKO - 12 Sep, 2003)
2 None: Re: NaI detector energy acquisition   (michel maire - 12 Sep, 2003)
 Add Message Add Message