Message: NaI detector energy acquisition Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question NaI detector energy acquisition 

Keywords: energy acquisition, histogram
Forum: Event and Track Management
Date: 01 Sep, 2003
From: Sean Turnbull <Sean Turnbull>

I am modelling a NaI detector with an incident 2.61 MeV gamma shower of something around 5-10E6 particles to compare against standard results.

I am wanting to histogram the pulse height spectrum.

What is the best method to accumulate the energy of each shower? I have a SD set for the NaI section of the detector and a short piece of code in EndOfEventAction to set up the pulse height spectrum to later plot.

Does this sound ok.... thanks sean

I can post code if this it too complicated.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: NaI detector energy acquisition   (michel maire - 02 Sep, 2003)
(_ None: Re: NaI detector energy acquisition   (Sean Turnbull - 04 Sep, 2003)
(_ None: Re: NaI detector energy acquisition   (Vladimir Ivantchenko - 04 Sep, 2003)
(_ Question: Re: NaI detector energy acquisition   (Sean Turnbull - 11 Sep, 2003)
1 None: Re: NaI detector energy acquisition   (Vladimir IVANTCHENKO - 12 Sep, 2003)
2 None: Re: NaI detector energy acquisition   (michel maire - 12 Sep, 2003)