Message: Re: Problems with Tracking in Vacuum Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Problems with Tracking in Vacuum 

Keywords: Step limit
Forum: Fields: Magnetic and Otherwise
Re: Question Problems with Tracking in Vacuum (Jens Hasper)
Re: None Re: Problems with Tracking in Vacuum (John Apostolakis)
Re: None Re: Problems with Tracking in Vacuum (Jens Hasper)
Re: None Re: Problems with Tracking in Vacuum (Makoto Asai)
Date: 28 Mar, 2006
From: Jens Hasper <hasper@ikp.tu-darmstadt.de>

Hello Makoto,

thanks for your response. Actually I hadn't defined the G4StepLimiter. But even after having defined it now, it still does not have any effect on the UserLimits. I used the following commands for every particle manager:

  G4StepLimiter* StepLimiter=new G4StepLimiter("StepLimiter");

  pmanager->AddProcess(StepLimiter);

Did I do any mistake or could there be anything else I might have forgotten when using the UserLimits?

Best regards,

Jens

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: Problems with Tracking in Vacuum   (Anton - 25 May, 2006)
 Add Message Add Message
to: "Re: Problems with Tracking in Vacuum"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]