Message: Re: cold neutron spin tracking Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: cold neutron spin tracking 

Forum: Fields: Magnetic and Otherwise
Re: Question cold neutron spin tracking (Emil Frlez)
Re: Question Re: cold neutron spin tracking (Emil Frlez)
Date: 23 Jun, 2010
From: Kosta Kliakhandler <Kosta Kliakhandler>

Hello,

Is there any way to control the accuracy of the integration?

I get about a 2 degree difference from an analytical solution for a field of ~0.6 Tm and 300 MeV momentum, in a constant field.

I tried to use almost all the integrators (at least the ones that should be potentially more accurate than ClassicalRK4), and they all perform the same or worse than ClassicalRK4. Step size does not seem to affect it either.

Thanks in advance.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: cold neutron spin tracking   (Gumplinger Peter - 24 Jun, 2010)
1 None: Re: cold neutron spin tracking   (Kosta Kliakhandler - 25 Jun, 2010)
(_ Feedback: Re: cold neutron spin tracking   (Gumplinger Peter - 25 Jun, 2010)
2 None: Re: cold neutron spin tracking   (John Apostolakis - 24 Jun, 2010)
1 None: Re: cold neutron spin tracking   (Kosta Kliakhandler - 25 Jun, 2010)
(_ Feedback: Re: cold neutron spin tracking   (Gumplinger Peter - 25 Jun, 2010)
(_ None: Re: cold neutron spin tracking   (Kosta Kliakhandler - 13 Jul, 2010)