Message: Re: pb using Magnetic field in vacuum. Track length depends on incident energy Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Idea Re: pb using Magnetic field in vacuum. Track length depends on incident energy 

Forum: Fields: Magnetic and Otherwise
Re: None pb using Magnetic field in vacuum. Track length depends on incident energy (sauvestre)
Date: 25 Feb, 2016
From: sauvestre <sauvestre>

In fact, if i am right, my problem is in the accuracy of the parameters.

If i increase both deltaChord, deltaOneStep and deltaIntersection up to 0.1 mm

the behavior i mentionned disappears.

Sorry for the uncorrect name of my snapshots (one must read electron rather than

 proton for the filename).

However, if i want to use volumes of rather small sizes ( say few microns ) and
 higher magnetic field, what are the general rules for these paramaters?

Thank you and Best regards JES

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Question: Re: pb using Magnetic field in vacuum. Track length depends on incident energy   (sauvestre - 25 Feb, 2016)
1 Feedback: Re: pb using Magnetic field in vacuum. Track length depends on incident energy   (Gumplinger Peter - 26 Feb, 2016)
(_ Ok: Re: pb using Magnetic field in vacuum. Track length depends on incident energy   (sauvestre - 26 Feb, 2016)
2 Feedback: Re: pb using Magnetic field in vacuum. Track length depends on incident energy   (Gumplinger Peter - 26 Feb, 2016)
1 Ok: Re: pb using Magnetic field in vacuum. Track length depends on incident energy   (sauvestre - 26 Feb, 2016)