Message: Energy conservation !!!!! Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Energy conservation !!!!! 

Forum: Fields: Magnetic and Otherwise
Date: 22 Apr, 2010
From: Davinder Siwal <Davinder Siwal>

Hiiiiii Geant4 Users

I am trying to calculate the theoretical detector pulses for this i shoot photons of energy 600Kev to the detector and run for 10 events many of these events fully absorb inside the detector but i am not getting about their energy loss fully when i turn on the electric field (it is going to be fine without electric field),like event2 which i am showing below

------------> Begin of Event:2
0
  trackID: 1  energy deposit: 11.1 keV  position: 24.5 -0.0417 -0.163 cm time: 176 ps 
  G4ParticleChange::CheckIt    : the global time goes back  !!
  Difference:  0.211[ns] 
  G4ParticleChange::CheckIt    : the proper time goes back  !!
  Difference:  0.159[ns] 
 G4ParticleChange::CheckIt 
      -----------------------------------------------
        G4ParticleChange Information  
      -----------------------------------------------
        # of 2ndaries       :                    0
      -----------------------------------------------
        Energy Deposit (MeV):                    0
        Track Status        :                Alive
        True Path Length (mm) :               0.0164
        Stepping Control      :                    0
        Mass (GeV)   :                    0
        Charge (eplus)   :                    0
        Position - x (mm)   :                  245
        Position - y (mm)   :               -0.428
        Position - z (mm)   :                -1.62
        Time (ns)           :                    0
        Proper Time (ns)    :               -0.159
        Momentum Direct - x :              0.00931
        Momentum Direct - y :               -0.696
        Momentum Direct - z :                0.718
        Kinetic Energy (MeV):                0.165
        Polarization - x    :                    0
        Polarization - y    :                    0
        Polarization - z    :                    0
        Track Weight      :                    0
        Touchable (pointer) :           0xac86c708

*** G4Exception : 200
      issued by : G4ParticleChange::CheckIt
momentum, energy, and/or time was illegal
*** Event Must Be Aborted 
  trackID: 4  energy deposit: 165 keV  position: 24.5 -0.0428 -0.162 cm time: 211 ps 
Total no. of hits by this event = 2
Total energy deposited by this event = 176 keV
Total events impinges = 3

----------------->End of event: 2

can anybody help me

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All