Re: Question insert Electric fileld to logical volume (Lee, Hyun-Seung)
Date: 22 Feb, 2008
From: Dan Shapira <Dan Shapira>

That was a nice and comprehensive response. Should add that the different
classes such as fLocalEquation, fLocalChord, etc must be defined either in 
header or but declaring them in line - for example:
fLocalEquation =  new G4EqMagElectricField(MyEField);
should be replaced by:
G4EqMagElectricField* fLocalEquation = 
                                 new G4EqMagElectricField(MyEField);
etc....