Message: Re: Multiple scorers with multiple Logical Volumes Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Multiple scorers with multiple Logical Volumes 

Forum: Biasing and Scoring
Re: Question Multiple scorers with multiple Logical Volumes (Matt Worden)
Date: 18 May, 2011
From: Tsukasa Aso <Tsukasa Aso>

Hi,

First of all,
in DetectorConstruction, your code setups following scoring structure.
   Does it match your aim?
   One MultiFunctioalDetector is attached to two different logical volumes.
   The scorers are called in both logical volumes.

  G4PSPassageCellCurrent -+                              +---(cellLogical)
  (socreCurrent)          |                              |   (scoringVolume)
                          +---G4MultiFunctionslDetector--+
  G4PSNofSecondary        |    (detector)                |    
  (totalscoreCurrent)-----+                              +--- (air_Logical)
                                                             (totalscoringVolume)


Tsukasa Aso

 Add Message Add Message
to: "Re: Multiple scorers with multiple Logical Volumes"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews