Respected Dr. Aso,

Many thanks for your reply. I have tried particle with kinetic energy filter and I do not get Compton edge in my spectrum. Also I need to simulate a detector response for 1000 energy bins, It will be great if you can help me with an example code. I also tried doing following:

/score/quantity/energyDeposit edep1
/score/filter/particleWithKineticEnergy f1 0 9.775171e-03 MeV e-
/score/quantity/energyDeposit edep2
/score/filter/particleWithKineticEnergy f2 9.775171e-03 1.955034e-02 MeV e-
/score/quantity/energyDeposit edep3
/score/filter/particleWithKineticEnergy f3 1.955034e-02 2.932551e-02 MeV e-
/score/quantity/energyDeposit edep4
/score/filter/particleWithKineticEnergy f4 2.932551e-02 3.910068e-02 MeV e-
/score/quantity/energyDeposit edep5
/score/filter/particleWithKineticEnergy f5 3.910068e-02 4.887586e-02 MeV e-
/score/quantity/energyDeposit edep6
/score/filter/particleWithKineticEnergy f6 4.887586e-02 5.865103e-02 MeV e-
/score/quantity/energyDeposit edep7
/score/filter/particleWithKineticEnergy f7 5.865103e-02 6.842620e-02 MeV e-


Also, please let me know that if I enter:
/score/filter/particleWithKineticEnergy f1 0. 1. MeV e-
--or--
/score/filter/kineticEnergy range0 0. 1. MeV

In the above two lines the range 0-1 MeV, is that energy deposited or Kinetic energy of the incoming particle? Because I need it to be energy deposited in x axis.

And In the csv file generated there is a column called 'entries', can that be taken as counts in yaxis?

Sir, my final aim is to get Energy deposited vs Counts. I will be very grateful of any insight you can provide me in this regard.

Thank you in advance!

Best regards,
Sanchit Sharma

________________________________
From: Tsukasa Aso <aso@nc-toyama.ac.jp>
Sent: Wednesday, March 6, 2019 7:17:18 AM
To: biasing_scoring-g4hn@SLAC.Stanford.EDU
Subject: Re: Geant4 simulation to obtain NaI spectrum (counts vs energy deposited)


*** Discussion title: Biasing and Scoring

Hi,

If you do not want to develop codes for scoring energy spectrum, the straightforward way is
to score energy deposit in each energy range.

For example,

/score/quantity/energyDeposit dep0  MeV
/score/filter/kineticEnergy range0 10. 20. MeV
/score/quantity/energyDeposit dep1  MeV
/score/filter/kineticEnergy range1 20. 30. MeV
......

Best regards

-------------------------------------------------------------
Visit this GEANT4 at hypernews.slac.stanford.edu message (to reply or unsubscribe) at:
http://hypernews.slac.stanford.edu/HyperNews/geant4/get/biasing_scoring/282/1.html

 [ MIME part of type text/html without a name stripped ]

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: Geant4 simulation to obtain NaI spectrum (counts vs energy deposited)   (Tsukasa Aso - Mar 06, 16:03)
2 None: Re: Geant4 simulation to obtain NaI spectrum (counts vs energy deposited)   (Tsukasa Aso - Mar 07, 02:10)
1 None: Re: Geant4 simulation to obtain NaI spectrum (counts vs energy deposited)   (Sanchit Sharma - Mar 07, 14:11)
 Add Message Add Message
to: "Re: Geant4 simulation to obtain NaI spectrum (counts vs energy deposited) "

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews