Message: Re: Geant4 not making source of 0.025 eV Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Feedback Re: Geant4 not making source of 0.025 eV 

Forum: Biasing and Scoring
Re: Question Geant4 not making source of 0.025 eV (Sanchit Sharma)
Date: Feb 04, 18:40
From: Jonathan Madsen <Jonathan Madsen>

What physics list are you using?

If you have not enabled HP (high-precision) for neutrons, it is likely that Geant4 is noticing there are not any applicable physics processes for the particle type at that energy level and disregarding that command.

Try using a physics list like QGSP_BERT_HP and see if the problem still exists.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Question: Re: Geant4 not making source of 0.025 eV   (Sanchit Sharma - Feb 08, 15:25)
 Add Message Add Message
to: "Re: Geant4 not making source of 0.025 eV"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews