Message: Re: G4MultiFunctionalDetector assign to more than one logical volume Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: G4MultiFunctionalDetector assign to more than one logical volume 

Forum: Biasing and Scoring
Re: Question G4MultiFunctionalDetector assign to more than one logical volume (Yuefeng Qiu)
Date: 24 Mar, 2014
From: Tsukasa Aso <Tsukasa Aso>

 HI,

> In my case, I have many G4LogicalVolumes (LV) being assigned to a
> G4MultiFunctionalDetector (for example 1000 LV which is different from
> each other). So the question is: How can I get results for each LV ?
> 
> The manual says that G4VPrimitiveScorer can be registered in
> G4MultiFunctionalDetector, and G4VPrimitiveScorer has a G4THitsMap.
> G4THitsMap maps "copy number" of the LV to a double value. If all my LV
> has no other copy, does it mean that all the results for these 1000 LV
> will be summed up and assign to value with key=0?

Yes, the result will be summed up and assigned to value with key=0.

If you want to separate the value of each LV with key, you can give a
copy number to your LV in the placement. Even if you actually has no copy,
you can assign a copy number to each LV to distinguish each LV.
The copy number will be referred from MultiFunctionalDetector and used 
as key number.

Best regards,
T. Aso

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: G4MultiFunctionalDetector assign to more than one logical volume   (Yuefeng Qiu - 24 Mar, 2014)
 Add Message Add Message
to: "Re: G4MultiFunctionalDetector assign to more than one logical volume"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews