Message: Re: 1-d histo from TestEm7 example Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: 1-d histo from TestEm7 example 

Forum: Analysis
Re: None 1-d histo from TestEm7 example (Steven Avery)
Date: 15 Dec, 2003
From: michel maire <michel maire>

User Steven Avery wrote:

>> can someone explain the units on the axes of the histogram produced from
>> the example in Geant4/examples/extended/electromagnetic/TestEm7. it says
>> the x-axis is depth(mm) and the y-axis is Edep(MeV/mm). if thats the
>> case then if you multiply the depth by the edep you should get the
>> energy. but you don't i could be wrong in my understanding. can someone
>> explain?
>> 
>> regards, steven

 It is the energy deposit per slice of 1 mm thick at a given depth.
 For instance the energy deposit between 60 mm and 61 mm is about
 6000 MeV. The energy deposit between 140 mm and 141 mm is 10000 MeV
 (the incident beam is 10000 protons).

        Michel