Message: compiling of geant4 examples- Xray telescope Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None compiling of geant4 examples- Xray telescope  

Forum: Analysis
Date: 09 Dec, 2003
From: R Gunasingha <R Gunasingha>

Hi,
   I installed Anaphe/Aida library again and compiled the advanced/xray-telescope example. Then I ran the executable with test.mac
 given in the example directory. It runs and gets only a 5 events and suddenly core dumps, giving the following messages. Is there something 
 wrong? It tells "segmentation violation".

  How can I set this to run smoothly.

Thank you,

Gunasingha ====================== Message ==========================

 [phguna@grb]# ./XrayTel test.mac 
**********************************************
 Geant4 version $Name: geant4-05-02-patch-01 $
                                (27-August-2003)
             Copyright : Geant4 Collaboration
**********************************************
Visualization Manager instantiating...
Visualization Manager initialising...
Registering graphics systems...

You have successfully chosen to use the following graphics systems.
Current available graphics systems are:
  ASCIITree (ATree)
  DAWNFILE (DAWNFILE)
  GAGTree (GAGTree)
  G4HepRepFile (HepRepFile)
  G4HepRep (HepRepXML)
  RayTracer (RayTracer)
  VRML1FILE (VRML1FILE)
  VRML2FILE (VRML2FILE)
phot:  Total cross sections from Sandia parametrisation. 
WARNING !
 SetCutValueForOthers became obsolete.
 It is harmless to remove this invokation without any side effects.
 This dummy method implementation will be removed soon.

compt:  Total cross sections from a parametrisation. Good description from 10 KeV to (100/Z) GeV. 
       Scattered gamma energy according Klein-Nishina.
        PhysicsTables from 1 keV to 100 GeV in 80 bins. 

conv:  Total cross sections from a parametrisation. Good description from 1.5 MeV to 100 GeV for all Z. 
        e+e- energies according Bethe-Heitler
        PhysicsTables from 1.022 MeV to 100 GeV in 100 bins. 

msc:   Tables of transport mean free paths.
          New model of MSC , computes the lateral 
          displacement of the particle , too.
        PhysicsTables from 100 eV  to 100 TeV in 100 bins. 
eIoni:  delta cross sections from Moller+Bhabha. Good description from 1 KeV to 100 GeV.
        delta ray energy sampled from  differential Xsection.
        PhysicsTables from 1 keV to 100 TeV in 100 bins.
        Step function: finalRange(mm)= 1,  dRoverRange= 0.2

eBrem:  Total cross sections from a NEW parametrisation based on the EEDL data library. 
 Good description from 1 KeV to 100 GeV.
        log scale extrapolation above 100 GeV 
        Gamma energy sampled from a parametrised formula.
        PhysicsTables from 1 keV to 100 TeV in 100 bins. 

annihil:  Total cross section from Heilter formula(annihilation into 2 photons).        gamma energies sampled according Heitler
        PhysicsTables from 10 keV to 10 TeV in 100 bins. 

msc:   Tables of transport mean free paths.
          New model of MSC , computes the lateral 
          displacement of the particle , too.
        PhysicsTables from 100 eV  to 100 TeV in 100 bins. 
G4AugerData for Element no. 6 are loaded
G4AugerData for Element no. 13 are loaded
G4AugerData for Element no. 14 are loaded
G4AugerData for Element no. 22 are loaded
G4AugerData for Element no. 28 are loaded
G4AugerData for Element no. 79 are loaded
AugerTransitionTable complete

hLowEIoni:    Knock-on electron cross sections . 
        Good description above the mean excitation energy.
        Delta ray energy sampled from  differential Xsection.
        PhysicsTables from 10 eV  to 0.1 TeV  in 360 bins.
        Electronic stopping power model is  ICRU_R49p
        from 1 keV  to 2 MeV .

        Parametrisation model for antiprotons is  ICRU_R49p
        from 25 keV  to 2 MeV .
        Parametrization of the Barkas effect is switched on.
        Nuclear stopping power model is ICRU_R49

msc:   Tables of transport mean free paths.
          New model of MSC , computes the lateral 
          displacement of the particle , too.
        PhysicsTables from 100 eV  to 100 TeV in 100 bins. 
### Run : 0
 HistTree store : xraytel.hbook
Booked Hbook File 
Start Run processing.
Run terminated.
Run Summary
  Number of events processed : 100000
  User=498.33s Real=505.03s Sys=0.5s
Committing...
Closing the tree...
End of Run summary

Total Entering Detector : 5 Total Entering Detector Energy : 1.81573 MeV Graphics systems deleted. Visualization Manager deleting... G4 kernel has come to Quit state.

 *** Break *** segmentation violation
 Generating stack trace...
 0x4453cc48 in <unknown> from /lib/i686/libc.so.6
 0x4003ae7c in <unknown> from /g4/Anaphe/release//specific/redhat73/gcc-3.2/5.0.5/lib/libHepUtilities.so
 0x400446b9 in <unknown> from /g4/Anaphe/release//specific/redhat73/gcc-3.2/5.0.5/lib/libHepUtilities.so
 0x4000ab92 in <unknown> from /lib/ld-linux.so.2
 0x4453f162 in exit + 0x72 from /lib/i686/libc.so.6
 0x445298dc in __libc_start_main + 0xac from /lib/i686/libc.so.6
 0x0804ecc9 in G4VUserPhysicsList::RetrievePhysicsTable(G4ParticleDefinition*, G4String const&, bool) + 0x41 from ./XrayTel
Abort (core dumped)

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: compiling of geant4 examples- Xray telescope   (Andreas Pfeiffer - 09 Dec, 2003)
 Add Message Add Message
to: "compiling of geant4 examples- Xray telescope "

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]