Dear all

I'm using geant 4.9.3 with VC++, cygwin and OpenScientist osc_vis 16.11 for windows. I did below set well.
$export G4ANALYSIS_USE=1
$export CPPVERBOSE=1
$unset G4ANALYSIS_AIDA_CONFIG_CFLAGS
$unset G4ANALYSIS_AIDA_CONFIG_LIBS

Running A01 example was fine. But when I ran medical linac 2 examples in geant 4.9.3, running was suddenly shutting down like below

*************************************************************
 Geant4 version Name: geant4-09-03 (18-December-2009)
                      Copyright : Geant4 Collaboration
                      Reference : NIM A 506 (2003), 250-303
                            WWW : http://cern.ch/geant4
*************************************************************

THE FOLLOWING ELECTROMAGNETIC PHYSICS LIST HAS BEEN ACTIVATED: G4EmLivermore
ics
Checking overlaps for volume acceleratorBox ... OK!
Checking overlaps for volume targetA ... OK!
Checking overlaps for volume targetB ... OK!
Checking overlaps for volume BeWTubePV ... OK!
Checking overlaps for volume ionizationChamberTubeW1PV ... OK!
Checking overlaps for volume ionizationChamberTubeP1PV ... OK!
Checking overlaps for volume ionizationChamberTubeW2PV ... OK!
Checking overlaps for volume ionizationChamberTubeP2PV ... OK!
Checking overlaps for volume ionizationChamberTubeW3PV ... OK!
Checking overlaps for volume ionizationChamberTubeP3PV ... OK!
Checking overlaps for volume FFL1A_1PV ... OK!
Checking overlaps for volume FFL2_1PV ... OK!
Checking overlaps for volume MirrorTubePV ... OK!
Checking overlaps for volume UpperCollimator ... OK!
Checking overlaps for volume CylMinusCone ... OK!
Checking overlaps for volume leafA0 ... OK!
Checking overlaps for volume leafA1 ... OK!
Checking overlaps for volume leafA2 ... OK!
Checking overlaps for volume leafA3 ... OK!
Checking overlaps for volume leafA4 ... OK!
Checking overlaps for volume leafA5 ... OK!
Checking overlaps for volume leafA6 ... OK!
Checking overlaps for volume leafA7 ... OK!
Checking overlaps for volume leafA8 ... OK!
Checking overlaps for volume leafA9 ... OK!
Checking overlaps for volume leafB0 ... OK!
Checking overlaps for volume leafB1 ... OK!
Checking overlaps for volume leafB2 ... OK!
Checking overlaps for volume leafB3 ... OK!
Checking overlaps for volume leafB4 ... OK!
Checking overlaps for volume leafB5 ... OK!
Checking overlaps for volume leafB6 ... OK!
Checking overlaps for volume leafB7 ... OK!
Checking overlaps for volume leafB8 ... OK!
Checking overlaps for volume leafB9 ... OK!
Checking overlaps for volume Jaws1XPV ... OK!
Checking overlaps for volume Jaws2XPV ... OK!
Checking overlaps for volume Jaws1YPV ... OK!
Checking overlaps for volume Jaws2YPV ... OK!
Checking overlaps for volume PhSpPV ... OK!
Checking overlaps for volume killerPlaneKPV ... OK!
Checking overlaps for volume phmWorldPV ... OK!
Checking overlaps for volume fullWaterPhantomPV ... OK!
ERROR I can't find the experimental data file
PhysicsList::SetCuts:CutLength : 1 mm
Visualization Manager instantiating...
Visualization Manager initialising...
Registering graphics systems...

You have successfully registered the following graphics systems.
Current available graphics systems are:
  ASCIITree (ATree)
  DAWNFILE (DAWNFILE)
  G4HepRep (HepRepXML)
  G4HepRepFile (HepRepFile)
  RayTracer (RayTracer)
  VRML1FILE (VRML1FILE)
  VRML2FILE (VRML2FILE)
  gMocrenFile (gMocrenFile)
  OpenGLImmediateWin32 (OGLIWin32)
  OpenGLStoredWin32 (OGLSWin32)

Registering model factories...

You have successfully registered the following model factories.
Registered model factories:
  generic
  drawByCharge
  drawByParticleID
  drawByOriginVolume
  drawByAttribute

Registered filter factories:
  chargeFilter
  particleFilter
  originVolumeFilter
  attributeFilter

G4Scene::AddWorldIfEmpty: The scene was empty of run-duration models.
  "world" has been added.
/tracking/storeTrajectory 1
WARNING: Trajectory storing has been requested. This action may be
  reversed with "/tracking/storeTrajectory 0".
WARNING: The vis manager will keep up to 100 events.
  This may use a lot of memory.
  It may be changed with, e.g., "/vis/scene/endOfEventAction accumulate 10".
Idle> /run/beamOn 50

Owner@snuh-a089e1ddd0 /cygdrive/c/g4work/medical_linac2
$
 

I appreciate your help in advance
Wonmo

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: Outputting Medical Linac via Openscientist   (Wonmo - 02 Jun, 2010)