Message: Re: how to add energy resolution code in geant4 Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: how to add energy resolution code in geant4 

Forum: Analysis
Re: None how to add energy resolution code in geant4 (ylzhang)
Date: 28 Apr, 2008
From: John Allison <John Allison>

Why do you want to add resolution? At each step, Geant4 gives a deposited energy that is drawn from the appropriate distribution - the Landau distribution - for that particle in that material. So its distribution - with some addition, perhaps, for electronic readout noise - should match your observed distribution.

You should think of the addition of electronic readout noise as a separate step, nothing to do with Geant4. It is often referred to as "digitisation". Geant4 just does the physics.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: how to add energy resolution code in geant4   (ylzhang - 01 May, 2008)
 Add Message Add Message
to: "Re: how to add energy resolution code in geant4"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews