Message: Re: Unexpected results for fluence and TID using Spenvis/GRAS Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Unexpected results for fluence and TID using Spenvis/GRAS 

Forum: Space Applications
Re: Question Unexpected results for fluence and TID using Spenvis/GRAS (Svetlana Shasharina)
Re: None Re: Unexpected results for fluence and TID using Spenvis/GRAS (Svetlana Shasharina)
Date: 10 Mar, 2016
From: Svetlana Shasharina <Svetlana Shasharina>

I ran the same example with higher fluences and the conclusion remains: in order to get the incident fluence (1/cm^2 s), I need to divide the result of GRAS/Spenvis by 2pi and multiply to 100.

I would like to have a similar simple case where I calculate TID analytically to compare TID to the calculated TID. Does anybody have a suggestion for a case when all incident particles energy would be absorbed? Or maybe there is a classic case which everybody trusts?

Thanks, Sveta