Message: extra parts add to TID: unexpected result Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question extra parts add to TID: unexpected result 

Forum: Space Applications
Date: 05 May, 2014
From: Svetlana Shasharina <Svetlana Shasharina>

Hi I am using SPENVIS/GRAS. I calculated fluxes and TIDs in two configurations: (1) cylindrical shield with an opening on top (2) the same shield plus a hollow cone sitting on the opening and having the same size of opening. I used the same fluxes and spherical source in both cases. To my surprise, the TID from electrons of the "detector" inside the cylindrical shields and a proton flux on them was higher in the second case. I then added calculations of fluxes from the cone and it was zero. Flux between the cone and the detector was zero too. I am puzzled by the result. Any ideas? Thanks, Sveta

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Note: Re: extra parts add to TID: unexpected result   (Svetlana Shasharina - 01 Jul, 2014)
 Add Message Add Message
to: "extra parts add to TID: unexpected result"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]