Message: Re: the calculation of absorbed dose through TestEm7 Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: the calculation of absorbed dose through TestEm7 

Keywords: TestEm7 absorbed dose
Forum: Medical Applications
Re: Sad the calculation of absorbed dose through TestEm7 (Shahrokh)
Date: 16 Aug, 2004
From: michel maire <michel maire>

 I tested your code:

 In dose.cc, you force runManager->Initialize() before to read the 
 macro rundose.mac. The geometry is initialized, and the definition
 of the tallies is not taken into account, as we can see with 
 tracking/verbose 1

 Remove this runManager->Initialize from dose.cc, 
 and put /run/initialize in your macro after the tallies definition.

                   Michel

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Question: Re: Other questions through TestEm7   (Shahrokh - 18 Aug, 2004)
(_ None: Re: Other questions through TestEm7   (michel maire - 20 Aug, 2004)
(_ Question: Re: Other questions through TestEm7   (Shahrokh - 29 Aug, 2004)