you can define a mesh box in macro file that is ranging from surface of phantom to desired depth (for example from depth = 0 to 30 cm ). then you can bin scoring box as follow: number of bins(1, 1, 300) if your scoring box dimension is for example (dx= 0.2 * dy = 0.2* dz = 300 mm)