Message: Re: DICOM extended example initial probems Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question Re: DICOM extended example initial probems 

Forum: Medical Applications
Re: Question DICOM extended example initial probems (Lara Mason)
Re: Feedback Re: DICOM extended example initial probems (Pedro Arce)
Re: Question Re: DICOM extended example initial probems (Lara Mason)
Date: 28 May, 2018
From: Lara Mason <Lara Mason>

Dear Pedro,

Should I change the names of the materials to the NIST database names? (eg G4_AIR)? And if so, how do I find the correct corresponding NIST material for those which do not directly translate such as LungInhale, LungExhale, Muscle?

Is this the reason for the problem I'm having, or is there another issue?

Thanks very much,

Lara

   Attachment:
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2018/05/28/07.01-17204-Data.dat

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Feedback: Re: DICOM extended example initial probems   (Pedro Arce - 28 May, 2018)
(_ None: Re: DICOM extended example initial probems   (Lara Mason - 30 May, 2018)
(_ Feedback: Re: DICOM extended example initial probems   (Pedro Arce - 30 May, 2018)
 Add Message Add Message
to: "Re: DICOM extended example initial probems"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews