Message: RE: brachytherapy analysis Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None RE: brachytherapy analysis 

Forum: Medical Applications
Re: Question brachytherapy analysis (mirvana)
Re: None Re: brachytherapy analysis (mirvana)
Date: 26 Jun, 2017
From: Susanna <Susanna>

If you mean how to obtain the dose from the energy deposition, the dose is the energy deposition divided by the mass of the voxel where the edep is deposited.
You can calculate this quantity post-processing from the current results of the simulation. An alternative solution is to  substitute
 /score/quantity/energyDeposit eDep with /score/quantity/doseDeposit dose
When defining the mash in the macro file (e.g. TG186SourceMacro.mac)

Cheers
Susanna

Dr Susanna Guatelli, 
Senior Lecturer and Academic Director of the Bachelor of Medical Radiation Physics,
School of Physics and Centre For Medical Radiation Physics, EIS,
University of Wollongong, Northfields Avenue, Wollongong, NSW 2522, Australia
Phone: 02 4221 4374



-----Original Message-----
From: mirvana [mailto:mirvana-hilal@hotmail.com] 
Sent: Monday, 26 June 2017 10:54 PM
To: medical_app-g4hn@slac.stanford.edu
Subject: Re: brachytherapy analysis


*** Discussion title: Medical Applications

and how can i obtain the dose from this energy?

-------------------------------------------------------------
Visit this GEANT4 at hypernews.slac.stanford.edu message (to reply or unsubscribe) at: 