Message: G4IAEAphspReader Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question G4IAEAphspReader 

Forum: Medical Applications
Date: 23 May, 2016
From: Thomas Bonnet <Thomas Bonnet>

Hello, I'm currently trying to run a simulation implementing a G4IAEAphspReader as a source. I'm using geant4-10-01-patch-01. I firstly used the G4IAEAphspInterface_v1.1 class available at https://www-nds.iaea.org/phsp/Geant4/ and followed the howto associated with it. The compilation badly failed because the signature of the G4Exception class used do not fit with the signature of the version of Geant4 I'm currently using.

I, then, tried to use the IAEA reader from there : https://github.com/EL-Bakkali-Jaafar/G4Linac/tree/master/G4Linac-head. This time, the code is correctly compiling but I see only one particle fired in my simulations wathever the number of events. The number of event is set using "/run/run/beamOn", I look for output with "/tracking/verbose 1" and I try to use the Phase Space ELEKTA_PRECISE_6mv_part1.

I can't find any example working and I'm wondering if this reader can still be used with the new versions of Geant4. Did any of you have success with it?

Regards.

Thomas

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Feedback: Re: G4IAEAphspReader   (Miguel Cortes-Giraldo - 23 May, 2016)
1 None: Re: G4IAEAphspReader   (Thomas Bonnet - 24 May, 2016)
2 None: Re: G4IAEAphspReader   (Eric Simiele - 10 Jun, 2016)