Message: Dose calculations using new stopping power data Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Dose calculations using new stopping power data 

Forum: Medical Applications
Date: 04 Nov, 2014
From: Metin Usta <Metin Usta>

Dear Geant4 Experts,

We want to do the dose calculations in extented/electromagnetic/TestEm7 example placing into Geant4 to the our obtained stopping power values which to be used in place of BraggModel and BetheBlochModel values. How can we do it? Can you make a sample data template (such as G4PSTARStopping.cc) which insert into the obtained energy and stopping power data? I would appreciate if you could help.

Best Regards,

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: Dose calculations using new stopping power data   (Vladimir Ivanchenko - 12 Nov, 2014)
 Add Message Add Message
to: "Dose calculations using new stopping power data"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]