Message: record particles in medical linac example Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None record particles in medical linac example 

Forum: Medical Applications
Date: 29 Nov, 2011
From: Eleni <Eleni>

Dear Geant4 experts,

Currently i am making a simulation of a medical linac and as a first stage I am trying to record the number of particle on the target and the physical processes. But I am getting the following error : ml2.cc:147: error: no matching function for call to ‘CML2SteppingAction::CML2SteppingAction(CML2Convergence*&, CML2RunAction*&)’

What I have done is to add a few code to ML2RunAction class in order to achieve my task.
 I am attaching the routines I changed
 I ll appreciate any suggestions in order to make it work!

 Thank you very much in advance

Eleni

   Attachment:
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2011/11/29/05.43-96343-ML2RunAction.cc
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2011/11/29/05.43-21334-ML2RunAction.hh
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2011/11/29/05.44-69083-ml2.cc

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: record particles in medical linac example   (Matej Batic - 30 Nov, 2011)