Message: Re: inhomogenity in water Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: inhomogenity in water 

Forum: Medical Applications
Re: None inhomogenity in water (riazi)
Date: 11 Nov, 2011
From: D. M. Tishler <D. M. Tishler>

I do not believe that proper scoring will occur in a parallel or overlapping geometry. I suggest using a modified CT file or even easier utilize GAMOS(http://fismed.ciemat.es/GAMOS/) to create a simple layered phantom. This will produce a DOSXYZ dose file containing dose in each of the phantom's voxels.

If you decide to try GAMOS, you can modify the following gamos script to do just what you need. It requires a file World.geom which contains the line:

:VOLU expHall BOX 25*cm 25*cm 100*cm G4_AIR

The gamos batch script is attached.

   Attachment:
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2011/11/11/08.06-49084-layers.txt