Message: DICOM: bug in 4.9.4.p01 example Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Note DICOM: bug in 4.9.4.p01 example 

Forum: Medical Applications
Date: 10 Jun, 2011
From: Asja Pfaffenberger <Asja Pfaffenberger>

In the extended/medical/DICOM example as it comes with geant4.9.4.p01 you need to fix a typo before you can produce results. The strings in DicomDetectorConstruction.cc, line 478, and DicomRunAction.cc, line 49 must be the same, so either change the former to "PhantomSD" or the latter to "phantomSD".

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Feedback: Re: DICOM: bug in 4.9.4.p01 example   (Pedro Arce - 10 Jun, 2011)
 Add Message Add Message
to: "DICOM: bug in 4.9.4.p01 example"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews