Message: medical_linac need clarification on VoxelTest.txt Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None medical_linac need clarification on VoxelTest.txt 

Forum: Medical Applications
Date: 30 May, 2011
From: Henry Wang <Henry Wang>

Hi,

How does x, y, z correspond to our image(512,512), say we use 1 image only. In this case will z=1?

Also, what exactly is dx, dy, and dz? should that be set to 1,1,0 if I'm interested in 1 pixel of my image at a time?

basically i want dose deposition at each pixel in my (512,512) image, how would I do this using x,y,z,dx,dy,dz? (1,1,0)(1,1,0)0 (1,2,0)(1,1,0)0 . .

Thanks, Henry

6 MeV Full Water Phantom Start 2 1 10 1 11 25 1 x y z dx dy dz dose (0, 0, -140) (5, 5 , 5) 0 (0, 0, -120) (5, 5 , 5) 0 (0, 0, -100) (5, 5 , 5) 0 (0, 0, -80) (5, 5 , 5) 0 (0, 0, -60) (5, 5 , 5) 0 (0, 0, -40) (5, 5 , 5) 0 (0, 0, -20) (5, 5 , 5) 0 (0, 0, 0) (5, 5 , 5) 0 (0, 0, 20) (5, 5 , 5) 0 (0, 0, 40) (5, 5 , 5) 0 (0, 140, 0) (5, 10 , 5) 0 (0, 120, 0) (5, 10 , 5) 0 (0, 100, 0) (5, 10 , 5) 0 (0, 80, 0) (5, 10 , 5) 0 (0, 60, 0) (5, 10 , 5) 0 (0, 40, 0) (5, 10 , 5) 0 (0, 20, 0) (5, 10 , 5) 0 (0, 0, 0) (5, 10 , 5) 0 (0, -20, 0) (5, 10 , 5) 0 (0, -40, 0) (5, 10 , 5) 0 (0, -60, 0) (5, 10 , 5) 0 (0, -80, 0) (5, 10 , 5) 0 (0, -100, 0) (5, 10 , 5) 0 (0, -120, 0) (5, 10 , 5) 0 (0, -140, 0) (5, 10 , 5) 0

   Attachment:
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2011/05/30/20.42-74453-VoxelsTest.txt

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: medical_linac need clarification on VoxelTest.txt   (Claudio Andenna - 06 Jun, 2011)
 Add Message Add Message
to: "medical_linac need clarification on VoxelTest.txt"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews