Dear Wang to get a smooth plot it is necessary to use much more primary particles (order of billions it depends also on the voxels size) especially when you use dicom images. Generally this is very time consuming and it could be useful to generate and use one or more phase space files. Furthermore, a particular attention should be paid also to the data files necessary to interpret the dicom images. Itís up to the user to correctly write these files since they correlate the CT numbers to the material they represent.