Message: Re: Geant vs EGS Dose-dept Disagreement Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Geant vs EGS Dose-dept Disagreement 

Forum: Medical Applications
Re: Question Geant vs EGS Dose-dept Disagreement (Nicole Ackerman)
Date: 14 Dec, 2010
From: michel maire <michel maire>

 We investigated a little bit more your situation. We ran TestEm7 with the macro in attachement.
 The first plot is like yours, with same results. The second plot is a zoom of the region 28 -> 32 mm
                           Michel

   Attachment:
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2010/12/14/09.47-62232-ackey.txt
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2010/12/14/09.48-44958-histo1.gif
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2010/12/14/09.48-8444-histo2.gif