Message: voxel phantom parameterisation and navigation with dose Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question voxel phantom parameterisation and navigation with dose 

Forum: Medical Applications
Date: 24 Sep, 2010
From: Mike <Mike>

I am new to Geant4 and would like to use its power to determine radiation dose deposited in specific organs using a voxelized phantom. I am using the 'old' DICOM example as a template with G4PVParameterisation (kUndefined).

However, I would like to transition to the new DICOM example and add either G4RegularNavigation/G4PhantomParameterisation or G4NestedParameterisation to speed up this sonofagun.

Is there a preferred one to use in my case of concentrating only on specific materials/tissues?

Thanks, Mike

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Feedback: Re: voxel phantom parameterisation and navigation with dose   (Pedro Arce - 24 Sep, 2010)
(_ Ok: Re: voxel phantom parameterisation and navigation with dose   (Mike - 27 Sep, 2010)