Dear Jongseok,

I ran some simulations and I realized that the main contribution to the peak you've seen is due to the brass final collimator (search for "HadrontherapyBeamFinalCollimator" in the file src/PassiveProtonBeamLine.cc).

The contribution due to the PMMA stopper is much less clear, and in any case, at slightly lower energies.

In any case the advanced example is meant to simulate a beam energy around 60 MeV (and with a Gaussian profile).

If you want to use it in other cases, you must change it.

Hope this helsp, enrico

> the second peak is due to the protons that, at 200 MeV, can bypass the
> PMMA stopper for the diffused radiation (search for
> "HadrontherapyBeamNozzle" in file src/PassiveProtonBeamLine.cc).
> 
> Hope this helps, Enrico
> 
> > /beam/energy/meanEnergy 200 MeV /beam/energy/sigmaEnergy 500 keV
> > /beam/position/Xposition -2000 mm
> 

 Add Message Add Message
to: "Re: 3-Dimensions Dosedistribution in Hadrontherapy."

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]