Dear Valery,

I have developed a code that calculates the dose deposited in each of the voxels of a phantom with their error, and dumps it to the standard output or/and to a file (or alternatively dumps error and error square for proper statistical summation of different jobs results), and it can also dump it into dose histograms: 1D, 2D, dose and dose-volume. You can find it at http://fismed.ciemat.es/GAMOS

My scorers inherit from the Geant4 class G4VPrimitiveScorer class, so you could use their error calculation in an standard Geant4 example. Nevertheless I think it will be easier to transform your example into a GAMOS one, and you will get some extra utilities of GAMOS (have a look at the User's Guide for more detail).

Pedro