Thanks for the quick response!

I downloaded and compiled 4.9.3-beta, hopefully I'll be able to try the Penelope model soon.

Vladimir: When you say there is a problem with my formula for stopping power what do you mean, specifically? I've got the ICRU reports(37&49) coming on interlibrary loan, but they might take a little while to arrive.

I found one source that said I should use the energy_lost/mean_path_length Rather than median path length or maximum path length. Is that what you mean?